Email: info@pmp-ltd.co.uk Home
     
 

Overview

Led by Andrew Taylor, PMP carries out ‘man entry’ surveys and structural condition assessments to potable water pipelines, foul sewers, surface water culverts, service reservoirs, draw-off systems and similar structures.

     

News

 
Achilles UVDB Verify
Adaptor for CIPP
Rope access with IRATA
Close fit liner solved
AMEX-10 Vario
 
 

The Confined Spaces Regulations 1997 advocates the use of remote inspection as the preferred method to survey confined spaces, with good reason. However, sometimes, remote inspections do not provide the information required by engineers to assist in decision making.

PMP can apply safe systems of work to safely carry out a man entry condition assessment from which the defects and consequential damage can be seen at first hand. Often the underlying cause of the the defects can also be seen. Using the most appropriate measuring, inspection, testing and communications equipment, we offer a wide range of confined space surveys.

Post-survey, we provide detailed condition reports and can, if requested, provide Method Statements and quotations for the most practical and effective repair options.